Time has witness all our effort to make CEM test braindumps: Certified Energy Manager (CEM) a brilliance in getting thousands of candidates out of the boring traditional study and paving the efficient and easy path for the AEE Certified Energy Manager (CEM) actual test to get the certification. The increasing high comments on our CEM study guide remark that the every work of our staff workers do for the test users is indispensable. We not only put high values on the practical effects of our CEM exam cram: Certified Energy Manager (CEM), but also try our best to meet all candidates need both in technological aspects and service experience. As a consequence, we have been improving the quality and strengthening service of our CEM exam dumps questions for so many years, making them nearly perfect to satisfy our users.
Latest questions and answers
Our exam materials designers will check all CEM test braindumps: Certified Energy Manager (CEM) regularly to ensure the update of practice questions and answers, after which the CEM exam guide questions users can get the latest information and most authentic materials so that contribute to the highest efficiency and the most excellent quality of study. So that never the users of CEM study guide questions will worry that the test out of date and miss the latest information. What If the customers purchase for CEM dumps torrent: Certified Energy Manager (CEM) a long time but within one year? Don't worry, neither, we also offer the free update for one year. What's more if you become the regular customers of our CEM VCE dumps questions, there will be more membership discount available.
Reliable and safe
Online privacy problem increasingly about purchasing CEM exam dumps become a hot issue in the modern life so that almost all shoppers worry about the privacy leaking when they take on the businesses on online payment platform. Among these people there is a part of our users of CEM test braindumps: Certified Energy Manager (CEM) unsurprisingly. However, the payment platform that our CEM study guide questions base on is quietly reliable and safe for at the present, which avoid the fraud transaction and guarantee the safety for our users of CEM exam guide questions. In addition, we keep the principle and follow it in our practical wok that under no circumstances, will we share the users'information of CEM test braindumps: Certified Energy Manager (CEM) with the third party without their consent.
After purchase, Instant Download: Upon successful payment, Our systems will automatically send the product you have purchased to your mailbox by email. (If not received within 12 hours, please contact us. Note: don't forget to check your spam.)
24/7 online customer service
We appreciate every comment our users of CEM exam guide make as much as we value each effort we do for our users. We do hope that all our users of CEM test braindumps: Certified Energy Manager (CEM) enjoy the best experience in their learning and practicing and are trying our best effort to achieve this. For that reason, we establish the special online customer service center to work with all the problem and trouble of the users of CEM study guide. Whatever the case is, our customer service staffs will never be absent there from receiving the users' information and find out the solution with their heart and soul.
AEE CEM Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Topic 1: Energy Audits and Instrumentation | 10% | - Audit levels and methodologies - Energy performance indicators - Data collection and analysis - Measurement tools and instrumentation |
| Topic 2: Electrical Power Systems and Motors | 15% | - Power distribution and quality - Motor systems, efficiency and controls - Power factor correction and load management |
| Topic 3: Operations, Maintenance and Commissioning | 5% | - Commissioning and retro-commissioning - Maintenance best practices |
| Topic 4: Building Automation and Controls | 5% | - Automation and optimization - Building management systems - Control systems and strategies |
| Topic 5: Distributed Generation and Renewable Energy | 4–6 | - Solar, wind, biomass, geothermal - Combined heat and power (CHP) - Grid integration and economics |
| Topic 6: Measurement and Verification | 5% | - M&V protocols and standards - Baseline development and savings calculation |
| Topic 7: Energy Storage Systems | 3–5 | - Storage technologies and applications - Integration and benefits |
| Topic 8: Boiler and Steam Systems | 4–6 | - Operation and efficiency - Maintenance and optimization |
| Topic 9: Industrial Systems | 6–8 | - Process energy efficiency - Compressed air, pumping, and drying systems |
| Topic 10: Lighting Systems | 10% | - Lighting technologies and efficiency - Design and control strategies - Daylighting integration |
| Topic 11: HVAC Systems and Building Envelope | 15% | - Thermal envelope performance - Heating, ventilation and air conditioning - Load calculation and system selection |
| Topic 12: Codes, Standards and Regulations | 5% | - Energy efficiency codes and standards - Compliance and reporting requirements - Sustainability policies and frameworks |
| Topic 13: Energy Accounting and Economics | 15% | - Life cycle costing and economic analysis - Time value of money, NPV, IRR, payback analysis - Utility rate structures and tariffs - Energy units and conversions |
| Topic 14: Energy Savings Performance Contracting | 5% | - Guaranteed savings and risk allocation - Contract structures and financing |
AEE Certified Energy Manager (CEM) Sample Questions:
1. A new energy-efficient boiler costs $60,890 to buy and install. The new energy-efficient boiler will save
$15,400 per year and last for 20 years. What is the internal rate of return (IRR) of the project?
A) 25%
B) 20%
C) 30%
D) 15%
E) 10%
2. Which of the following controls can optimize the operation of lighting systems?
A) All of the above
B) Photocells
C) Dimming ballasts
D) Occupancy sensors
E) Timer
3. In a warehouse, lights are mounted 4 meters above the floor. This provides an average light level of 150 lux.
To increase the light level without installing more lights or higher Wattage lights, you lower the light fixtures with pendants so that the lights are located 3.25 meters above the floor. Calculate the new average light level on the floor.
A) 227 lux
B) 276 lux
C) 166 lux
D) 176 lux
E) 150 lux
4. If installed without ancillary equipment, photovoltaic power cells generate what type of power?
A) Direct current
B) Sinusoidal alternating current
C) Square-wave alternating current
5. An energy-saving project costs $540,000. The project will have maintenance costs of $25,000 per year. The energy savings from the project are $160,000 per year. What is the simple payback of the project?
A) 3.0 years
B) 2.0 years
C) 5.0 years
D) 4.0 years
Solutions:
| Question # 1 Answer: B | Question # 2 Answer: A | Question # 3 Answer: A | Question # 4 Answer: A | Question # 5 Answer: D |